% File: rcs2
% $Name:  $

%
%----------------------------------------------------------------------
%		RCS VALVE CONTROL SYSTEM  - LOW LEVEL
%----------------------------------------------------------------------



bad_circuitry(V) :- elec_circ(C),
                    controls(Sw,V,C).


%bad_circuitry(V) :- elec_circ(C),
%                    commands(CC,V,S,C).








%%%%%%%%%%%%%%%%%% 	    Module: SWITCHES	       %%%%%%%%%%%%%%%% 
%%%%%%%%%%%%%%%%%%%%%%%%%%%	RULES	   %%%%%%%%%%%%%%%%%%%%%%%%%%%%%


% Normal behavior of switches on this level is described by the 
% following rules:

% If switch D is in state S and value X is present on input Wi 
% (which corresponds to S) at time T, then the output Wo paired  
% with Wi will also have value X at time T.

h(value(Wo,X),T) :- time(T),
		    signal(X),
		    connects(S,D,Wi,Wo),
		    h(in_state(D,S),T),
		    h(value(Wi,X),T),
		    not bad_connections_in(D).

% If switch D is in state S at time T, then output wires of all
% pairs corresponding to states different from S will have value 0
% at time T.

h(value(Wo,0),T) :- time(T),
                    state_of(S,v_switch),
                    h(in_state(D,S),T),
                    connects(S1,D,Wi,Wo),
                    neq(S,S1). 



% Bad connections in a device are expressed by 

%bad_connections_in(D) :- of_type(D,Dev),
%                         state_of(S,Dev),
%                         stuck(D,S).


%%%%%%%%%%%%%%%%%% 	End of Module: SWITCHES       %%%%%%%%%%%%%%%%%% 



%%%%%%%%%%%%%%%%%% 	    Module: VALVES	       %%%%%%%%%%%%%%%%%
%%%%%%%%%%%%%%%%%%%%%%%%%%%	FACTS	   %%%%%%%%%%%%%%%%%%%%%%%%%%%%%

% type_of_valve(V,Y) is true iff type of valve V is Y.

% Forward RCS

type_of_valve(ffha,solenoid).  % have 2 input wires: open & close
type_of_valve(foha,solenoid).
type_of_valve(ffhb,solenoid).
type_of_valve(fohb,solenoid).

type_of_valve(ffi12,motor3).   % have 3 input wires: open, closea & closeb
type_of_valve(foi12,motor3).
type_of_valve(ffi345,motor3).
type_of_valve(foi345,motor3).

type_of_valve(ffm1,motor2).    % have 2 input wires: open & close
type_of_valve(fom1,motor2).
type_of_valve(ffm2,motor2).
type_of_valve(fom2,motor2).
type_of_valve(ffm3,motor2).
type_of_valve(fom3,motor2).
type_of_valve(ffm4,motor2).
type_of_valve(fom4,motor2).

type_of_valve(ffm5,solenoid).   % have 2 input wires: open & close
type_of_valve(fom5,solenoid).


% Left RCS

type_of_valve(lfha,solenoid).   % have 2 input wires: open & close
type_of_valve(loha,solenoid).
type_of_valve(lfhb,solenoid).
type_of_valve(lohb,solenoid).

type_of_valve(lfi12,motor4).    % have 4 inputs: opena,openb,closea & closeb
type_of_valve(loi12,motor4).
type_of_valve(lfi345a,motor2).  % have 2 input wires: open & close
type_of_valve(loi345a,motor2).
type_of_valve(lfi345b,motor2).
type_of_valve(loi345b,motor2).

type_of_valve(lfm1,motor2).     % have 2 input wires: open & close
type_of_valve(lom1,motor2).
type_of_valve(lfm2,motor2).
type_of_valve(lom2,motor2).
type_of_valve(lfm3,motor2).
type_of_valve(lom3,motor2).
type_of_valve(lfm4,motor2).
type_of_valve(lom4,motor2).

type_of_valve(lfm5,solenoid).   % have 2 input wires: open & close
type_of_valve(lom5,solenoid).

type_of_valve(lfx12,motor4).    % have 4 inputs: opena,openb,closea & closeb
type_of_valve(lox12,motor4).
type_of_valve(lfx345,motor4).
type_of_valve(lox345,motor4).


% Right RCS

type_of_valve(rfha,solenoid).   % have 2 input wires: open & close
type_of_valve(roha,solenoid).
type_of_valve(rfhb,solenoid).
type_of_valve(rohb,solenoid).

type_of_valve(rfi12,motor4).    % have 4 inputs: opena,openb,closea & closeb
type_of_valve(roi12,motor4).
type_of_valve(rfi345a,motor2).  % have 2 input wires: open & close
type_of_valve(roi345a,motor2).
type_of_valve(rfi345b,motor2).
type_of_valve(roi345b,motor2).

type_of_valve(rfm1,motor2).     % have 2 input wires: open & close
type_of_valve(rom1,motor2).
type_of_valve(rfm2,motor2).
type_of_valve(rom2,motor2).
type_of_valve(rfm3,motor2).
type_of_valve(rom3,motor2).
type_of_valve(rfm4,motor2).
type_of_valve(rom4,motor2).

type_of_valve(rfm5,solenoid).   % have 2 input wires: open & close
type_of_valve(rom5,solenoid).

type_of_valve(rfx12,motor4).    % have 4 inputs: opena,openb,closea & closeb
type_of_valve(rox12,motor4).
type_of_valve(rfx345,motor4).
type_of_valve(rox345,motor4).



%%%%%%%%%%%%%%%%%%%%%%%%%%%	RULES	   %%%%%%%%%%%%%%%%%%%%%%%%%%%%%


% Solenoid controlled valves (and also type "Motor2" valves) have two input 
% wires which correspond to OPEN or CLOSE valve operations, and an additional 
% input for power supply. 
% The state of a solenoid valve is determined on this level of abstraction
% by rule

% CHANGED BY MARCELLO (09/27/00)
% Added neq(S,power_bus) and neq(S1,power_bus), in order to prevent the
% valve from moving to state "power_bus".
%

h(in_state(V,S),T) :- time(T),
                      v_solenoid(V),
                      input(W1,V),
                      input_of_type(W1,S),
		      neq(S,power_bus),
                      h(value(W1,1),T),
                      input(W2,V),
                      input_of_type(W2,S1),
		      neq(S1,power_bus),
                      h(value(W2,0),T),
                      neq(S,S1),
                      not stuck(V,S1).

v_solenoid(V) :- type_of_valve(V,solenoid).
v_solenoid(V) :- type_of_valve(V,motor2).


% Motor controlled valves type "motor3" differ from solenoid controlled 
% valves in that the former have input wires corresponding to: OPEN, 
% CLOSE-A and CLOSE-B, plus an additional input reserved for connection to a
% power bus source. However, motor controlled valves also have two output  
% wires for OPEN and CLOSE states as the solenoid controlled valves. 
%
% There are only two combinations of inputs that will appropriately
% activated the motor that controls the valve: 
% a. to close the valve the value of its input OPEN must be 0, and both
%    CLOSE-A and CLOSE-B inputs must be 1;
% b. to open the valve the value of its input OPEN must be 1, and the
%    value of input CLOSE-B must be 0.
% All other combinations of input values will not start the motor.
%
% The rules that represent the two operational conditions for opening/
% closing a motor controlled valve type "motor3" are  


h(in_state(V,closed),T) :- time(T),
                           type_of_valve(V,motor3),
                           input(W1,V),
                           input_of_type(W1,open),
                           h(value(W1,0),T),
                           input(W2,V),
                           input_of_type(W2,closea),
                           h(value(W2,1),T),
                           input(W3,V),
                           input_of_type(W3,closeb),
                           h(value(W3,1),T),
                           not stuck(V,open).

h(in_state(V,open),T) :- time(T),
                         type_of_valve(V,motor3),
                         input(W1,V),
                         input_of_type(W1,open),
                         h(value(W1,1),T),
                         input(W2,V),
                         input_of_type(W2,closeb),
                         h(value(W2,0),T),
                         not stuck(V,closed).


% For motor controlled valve type "motor4" we have

% Valve closes if both closea and closeb inputs are 1 and both
% opena and openb inputs are 0.
 
h(in_state(V,closed),T) :- time(T),
                           type_of_valve(V,motor4),
                           input(W1,V),
                           input_of_type(W1,opena),
                           h(value(W1,0),T),
                           input(W2,V),
                           input_of_type(W2,openb),
                           h(value(W2,0),T),
                           input(W3,V),
                           input_of_type(W3,closea),
                           h(value(W3,1),T),
                           input(W4,V),
                           input_of_type(W4,closeb),
                           h(value(W4,1),T),
                           not stuck(V,open).


% If at least one of the open inputs is 1 then valve opens.

h(in_state(V,open),T) :- time(T),
                         type_of_valve(V,motor4),
                         input(W1,V),
                         input_of_type(W1,opena),
                         h(value(W1,1),T),
                         not stuck(V,closed).


h(in_state(V,open),T) :- time(T),
                         type_of_valve(V,motor4),
                         input(W1,V),
                         input_of_type(W1,openb),
                         h(value(W1,1),T),
                         not stuck(V,closed).



% Values on output wires of both solenoid and motor controlled valves 
% are determined by rules:

% If valve V is in state S at time T, then the value on the
% output wire (corresponding to S) of V is 1 at T when V is powered.

%
% changed by marcy (10/18/02)
%
% until we further investigate the subject, we will
% not distinguish between the time taken by a solenoid
% valve to generate its output and the time taken by
% a non-solenoid valve.
%

h(value(W,1),T) :- time(T),
                   of_type(V,valve),                   
%                   type_of_valve(V,solenoid),
                   h(in_state(V,S),T),
                   output(W,V),
                   output_of_type(W,S),
                   input(Wp,V),
                   input_of_type(Wp,power_bus),
                   h(value(Wp,1),T).

%h(value(W,1),T1) :- next(T,T1),
%                    of_type(V,valve),                   
%                    not type_of_valve(V,solenoid),
%                    h(in_state(V,S),T),
%                    output(W,V),
%                    output_of_type(W,S),
%                    input(Wp,V),
%                    input_of_type(Wp,power_bus),
%                    h(value(Wp,1),T).
                                                
%%%% ATTENTION: be sure that we have power buses connected to valves
%%%% no control buses.


% Values on ouput wires of a valve V indicate the state of V, and
% are therefore multually exclusive under normal behavior.  If an 
% output wire has a value 1 at time T, then the value on the other 
% output wire is 0 at T.

h(value(W2,0),T) :- time(T),                          
                    of_type(V,valve),                     
                    output(W1,V),
                    output(W2,V),                     
                    neq(W1,W2),
                    h(value(W1,1),T).                    


% If a valve has no power (abnormal condition) then all its output 
% wires have value 0.

h(value(W,0),T) :- time(T),
                   of_type(V,valve),
                   output(W,V),
                   input(Wp,V),
                   input_of_type(Wp,power_bus),
                   h(value(Wp,0),T).


%%%% ATTENTION: be sure that we have power buses connected to valves
%%%% no control buses.



%%%%%%%%%%%%%%%%%% 	 End of Module: VALVES        %%%%%%%%%%%%%%%%%




%%%%%%%%%%%%%%%%%% 	   Module: POWER BUS          %%%%%%%%%%%%%%%%%

% Different power buses of both d.... (dc) and alternating current (ac)
% provide electrical power to the RCS to allow the operation of switches,
% valves, and other devices. These diverse sources of energy will be
% represent by power buses activated through manual on/off switches.  ???????


%%%%%%%%%%%%%%%%%%%%%%%%%%%	RULES	   %%%%%%%%%%%%%%%%%%%%%%%%%%%%

%
% For simplicity, a power bus will be modeled as a device with no inputs 
% and a single output which is always 1 under normal functioning conditions.
% If the power bus is faulty its output will have value 0. 

h(value(W,1),T) :- time(T),
                   of_type(D,power_bus),
                   output(W,D),
                   not bad_device(D).

h(value(W,0),T) :- time(T),
                   of_type(D,power_bus),
                   output(W,D),
                   bad_device(D).


%%%%%%%%%%%%%%%%%% 	End of Module: POWER BUS      %%%%%%%%%%%%%%%%%



%%%%%%%%%%%%%%%%%% 	  Module: CONTROL BUS         %%%%%%%%%%%%%%%%%



%%%%%%%%%%%%%%%%%%%%%%%%%%%	RULES	   %%%%%%%%%%%%%%%%%%%%%%%%%%%%

%
% For simplicity, a control bus will be modeled as a device with no inputs 
% and a single output which is always 1 under normal functioning conditions.
% If the control bus is faulty its output will have value 0. 

h(value(W,1),T) :- time(T),
                   of_type(D,control_bus),
                   output(W,D),
                   not bad_device(D).

h(value(W,0),T) :- time(T),
                   of_type(D,control_bus),
                   output(W,D),
                   bad_device(D).


%%%%%%%%%%%%%%%%%% 	End of Module: CONTROL BUS      %%%%%%%%%%%%%%%%%



%%%%%%%%%%%%%%%%%% 	Module: COMPUTER COMMAND      %%%%%%%%%%%%%%%%%

% The space shuttle flight computer software is contained in its five
% general purpose computers (GPCs) which control the vehicle. The data
% processing system (DPS) allows control of all RCS activity being
% responsible for transmiting commands for valve configuration and jet
% firings. 
% If a switch is placed in GPC state, computer commands can be output 
% to open or close the affected valves. 
% Issuing a computer command is represented as an action that will
% affect a target device D by setting D to a new state.


%%%%%%%%%%%%%%%%%%%%%%%%%%%	RULES	   %%%%%%%%%%%%%%%%%%%%%%%%%%%%

% Issuing a computer command CC is expressed on this level by applying
% a value of 1 on the wire connecting CC to a gate in the circuit.
 
h(value(W,1),T1) :- next(T,T1),		% marcy (10/18/02) -- for consistency with the way time flows during flip actions
%		   time(T),
                   commands(CC,V,S),
                   output(W,CC),
%                   occurs(cc(V,S),T).
                   occurs(CC,T).	% modified by marcy (10/18/02) -- CC's do not have the cc(V,S) form in the Extended VCM


% On the absence of computer commands, a signal of value 0
% should be present on the wires that connect some device of 
% an electrical circuit to the computers.

h(value(W,0),T) :- time(T),
                   commands(CC,V,S),
                   output(W,CC),
                   not h(value(W,1),T).


%%%%%%%%%%%%%%%     End of Module: COMPUTER COMMAND      %%%%%%%%%%%%%%	    